FAAC E145 Control Board
Shop By Categories
FAAC E145 Control Board
$ 350.00
Secure Payment

Details
FAAC E145 Control Board
The E145 can control one or two swinging door operators, a sliding gearmotor or mixed systems of swinging-sliding doors.
It is compatible with all receivers (3-pin or 5-pin or external) and all photocells (BUS as well as traditional).
Technical specifications
Power supply voltage |
SMPS from 90Vac to 260Vac 50/60 Hz |
Absorbed power |
4W Standby (2W on sleep) |
Motor max load |
800W |
Accessories max load |
500mA 24VDC 500mA BUS 2-EASY |
Operating temperature |
-20 °C to +55 °C |
Pause time |
Adjustable from 0 to 9 min 50 seconds |
Inputs |
Open Open pedestrian leaf Stop BUS 2-EASY Safety in opening Safety in closing Power supply + earth opening and closing limit switches |
Outputs |
Flashing lamp Motors 24Vds supply accessories 2 programmable outputs 2 electric locks |
Power supply voltage |
SMPS from 90Vac to 260Vac 50/60 Hz |
Absorbed power |
4Watt Stand by (2W with ”sleep mode”) |
Motor max.load |
800 Watt |
Accessories max.load |
500 mA 24VDC – 500mA BUS 2-easy |
Operating ambient temperature |
-20o to +55oC |
Electric lock max. load |
Faac lock (12VAC-24VDC) – not FAAC 24VDC-500mA |
Function logics |
Semiautomatic / Stepped semiautomatic / Safety Automatic / Automatic with reverse in pause / stepped Automatic / Safety automatic stepped / Automatic / Automatic 1 / Automatic with timer function / Semiautomatic B / Mixed (AP with pulse / CH with ”Dead man” / Dead man C / Custom (PC/MAC) |
Pause time |
Independently programmable after total or partial opening (from 0 to 9min 50sec) |
Motor numbers |
Selectable |
Thrust power |
Adjustable on 50 levels for each motor |
Terminal board inputs |
Open / Open pedestrian leaf / Stop (closed) / Bus 2easy / Safety in opening / Safety in closing / Power supply + earth / opening and closing limit switches |
Terminal board outputs |
Flashing lamp / Motors / 24Vdc supply accessories / 2 programmable OUTPUTS (default: indicator light and fail-safe) 2 electric locks |
Status signalling |
LCD Display and led |
Working Time learning |
Easy self-learning (max 4min and 10sec) Self-learning working time and deceleration of two leaves in one complete working cycle only with absolute SAFEcoder encoder the open/closed/deceleration positions are kept in memory |
Anti-crushing sensitivity |
Programmable if the ENCODER is present (10 levels) |
Maximum torque at initial thrust |
Selectable |
Cycle count |
Selectable (upgrade of a ”count-down” – max.setting 99.000 cycles) |
Service request |
Selectable (when the number of cycles set by program is ”reached”, the system activates a preflashing of 8s before every movement) |